Water Heater Management 0x0095
Controls water heater operations including temperature setpoints, modes, and boost heating.
Attributes 4
Commands 4
Features 1
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | TariffUnit | TariffUnitEnum | |
| 0x0001 | Currency | CurrencyStruct | |
| 0x0002 | CurrentPrice | CommodityPriceStruct | |
| 0x0003 | PriceForecast | array | Optional |
| Code | Name | Direction | Parameters |
|---|---|---|---|
| 0x00 | GetDetailedPriceRequest Optional | client→server |
Details: CommodityPriceDetailBitmap |
| 0x01 | GetDetailedPriceResponse Optional | server→client |
CurrentPrice: CommodityPriceStruct |
| 0x02 | GetDetailedForecastRequest Optional | client→server |
Details: CommodityPriceDetailBitmap |
| 0x03 | GetDetailedForecastResponse Optional | server→client |
PriceForecast: CommodityPriceStruct |
Forecasting
(FORE)
bit 0
Forecasts upcoming pricing
Devices Implementing This Cluster
2 devices in the survey implement this cluster