Zone Management 0x0550

Matter master
ClusterRevision 1
This cluster provides an interface to manage regions of interest, or Zones, which can be either manufacturer or user defined.

Spec History

Attributes (7)

Code Name Type
0x0000 MaxUserDefinedZones int8u
0x0001 MaxZones int8u
0x0002 Zones array
0x0003 Triggers array
0x0004 SensitivityMax int8u
0x0005 Sensitivity int8u
0x0006 TwoDCartesianMax TwoDCartesianVertexStruct

Commands (6)

Code Name Direction
0x00 CreateTwoDCartesianZone client→server
0x01 CreateTwoDCartesianZoneResponse server→client
0x02 UpdateTwoDCartesianZone client→server
0x03 RemoveZone client→server
0x04 CreateOrUpdateTrigger client→server
0x05 RemoveTrigger client→server

Features (4)

Bit Code Name
0 TWODCART TwoDimensionalCartesianZone — Supports Two Dimensional Cartesian Zones
1 PERZONESENS PerZoneSensitivity — Supports a sensitivity value per Zone
2 USERDEFINED UserDefined — Supports user defined zones
3 FOCUSZONES FocusZones — Supports user defined focus zones