Matter Survey

Community-basierte Datenbank für Matter-Gerätefunktionen

Electrical Energy Measurement 0x0091

Matter 1.4
ClusterRevision 2
This cluster provides a mechanism for querying data about the electrical energy imported or provided by the server.

Attributes (6)

Code Name Type
0x0000 Accuracy MeasurementAccuracyStruct
0x0001 CumulativeEnergyImported EnergyMeasurementStruct
0x0002 CumulativeEnergyExported EnergyMeasurementStruct
0x0003 PeriodicEnergyImported EnergyMeasurementStruct
0x0004 PeriodicEnergyExported EnergyMeasurementStruct
0x0005 CumulativeEnergyReset CumulativeEnergyResetStruct

Features (6)

Bit Code Name
0 IMPE ImportedEnergy — Measurement of energy imported by the server
1 EXPE ExportedEnergy — Measurement of energy provided by the server
2 CUME CumulativeEnergy — Measurements are cumulative
3 PERE PeriodicEnergy — Measurements are periodic
4 APPE ApparentEnergy — Measurements report apparent energy
5 REAE ReactiveEnergy — Measurements report reactive energy