The Humidistat cluster (0x0205) is a Matter cluster that Setpoint and humidification/dehumidification control for devices that regulate ambient humidity.. It defines 1 command and 14 attributes.

Humidistat 0x0205

Application Cluster
Comfort
Provisional
Introduced in: Matter master
Devices: 0
Setpoint and humidification/dehumidification control for devices that regulate ambient humidity.

Spec History

This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.

Attributes 14
Commands 1
Features 10
Code Name Type Flags
0x0000 SupportedModes array
0x0001 Mode
max 0x03
ModeEnum Writable
0x0002 SystemState
max 0x03
SystemStateEnum
0x0003 UserSetpoint
max 100
percent Writable Optional
0x0004 MinSetpoint
max 99
percent Optional
0x0005 MaxSetpoint
1..100
percent Optional
0x0006 Step
max 100
percent Optional
0x0007 TargetSetpoint
max 100
percent Optional
0x0008 MistType
max 0x03
MistTypeBitmap Writable Optional
0x0009 Continuous boolean Writable Optional
0x000A Sleep
default 0
boolean Writable Optional
0x000B Optimal boolean Writable Optional
0x000C CondPumpEnabled boolean Writable Optional
0x000D CondRunCount int16u Optional
Code Name Direction Parameters
0x00 SetSettings
This command will set the specified settings to new values.
client→server
UserSetpoint: percent, Mode: ModeEnum, MistType: MistTypeBitmap, Continuous: boolean, Sleep: boolean, Optimal: boolean
Humidifier (HUM) bit 0
Supports increasing the humidity in a space
Dehumidifier (DEHUM) bit 1
Supports decreasing the humidity in a space
Continuous (CONT) bit 2
Supports continuous humidity operation
Sensor (SENSOR) bit 3
Supports humidity control to a setpoint via an humidity sensor
Auto (AUTO) bit 4
Supports automatically switching operating states to maintain a set humidity
FanOnly (FAN) bit 5
Supports running the fan alone without humidity control
Optimal (OPT) bit 6
Supports controlling to an optimal humidity
WarmMist (WARM) bit 7
Supports warm mist operation
ColdMist (COLD) bit 8
Supports cold mist operation
CondPump (COND) bit 9
Supports control and monitoring of a condensate pump