The General Diagnostics cluster (0x0033) is a Matter cluster that Reports general device health metrics including uptime, reboot counts, and hardware faults.. It defines 5 commands and 10 attributes and is mandatory for 1 device type.
General Diagnostics 0x0033
Reports general device health metrics including uptime, reboot counts, and hardware faults.
Spec History
This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.
Attributes 10
Commands 5
Features 1
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | NetworkInterfaces | array | |
| 0x0001 | RebootCount | int16u | |
| 0x0002 | UpTime | int64u | Optional |
| 0x0003 | TotalOperationalHours | int32u | Optional |
| 0x0004 |
BootReason
max 0x06
|
BootReasonEnum | Optional |
| 0x0005 | ActiveHardwareFaults | array | Optional |
| 0x0006 | ActiveRadioFaults | array | Optional |
| 0x0007 | ActiveNetworkFaults | array | Optional |
| 0x0008 | TestEventTriggersEnabled | boolean | |
| 0x000A | DeviceLoadStatus | DeviceLoadStruct | Optional |
| Code | Name | Direction | Parameters |
|---|---|---|---|
| 0x00 |
TestEventTrigger
This command SHALL be supported to provide a means for certification tests to trigger some test-plan-specific events, necessary to assist in automation of device interactions for some certification test cases.
|
client→server |
EnableKey: octet_string, EventTrigger: int64u |
| 0x01 |
TimeSnapshot
Provisional
This command MAY be used by a client to obtain a correlated view of both System Time, and, if currently synchronized and supported, "wall clock time" of the server.
|
client→server | None |
| 0x02 |
TimeSnapshotResponse
Provisional
This command SHALL be generated in response to a TimeSnapshot command.
|
server→client |
SystemTimeMs: systime_ms, PosixTimeMs: posix_ms |
| 0x03 |
PayloadTestRequest
Optional This command provides a means for certification tests or manufacturer's internal tests to validate particular command handling and encoding constraints by generating a response of a given size.
|
client→server |
EnableKey: octet_string, Value: int8u, Count: int16u |
| 0x04 |
PayloadTestResponse
Optional This command is sent by the server on receipt of the PayloadTestRequest command.
|
server→client |
Payload: long_octet_string |
DataModelTest
(DMTEST)
bit 0
Support specific testing needs for extended Data Model features
Device Types Using This Cluster
Device types in the Matter spec that reference this cluster
Devices Implementing This Cluster
645 devices in the survey implement this cluster
Smart-Home-Bridge JS
Schoenberger
WiZ LED Strip
Signify
Smart Light
Uascent
Smart Switch
MS
Tapo Smart Wi-Fi In-wall Outlet
Tapo
Shelly 1PM Mini Gen3
Shelly
Cup Lamp
Umbra
Wi-Fi Smart Plug
SONOFF
2BMOG-LKMSD411A
LOCKIN (U.S.) INC.
Philips A19
Signify
WiZ A.E27
Signify
Govee RGBWW Smart LED Bulb
Govee
00176655
Hama GmbH
WiZ G95 Filament
Signify
Glass touch controller in an elegant black or white glass variant - 8 mm width
ELKO EP, s.r.o.
Tedee GO2
Tedee
Cync Indoor Light Strip 16ft
GE Lighting, a Savant company
TNKPLU261
tink GmbH
LIFX A19
Feit Electric
Smart RGBTW Bulb
Leedarson
Smart Rainbow LED
MOMAX Technology (Hong Kong) Limited
Dreame Aqua10 Ultra Track Complete
Dreame
Spotless Cleaning Robot
Bosch / Siemens / Gaggenau / Neff - Home Appliances
BHT-18
Beca